Water is the starting point of every grow, and every grow is different. Source water, growing medium, strain, nutrient program, room design, and the grower's objective all change what the water needs to be. There is no one size fits all in cannabis, and there is no single technology that does the job. ITS has the full range of technologies available, and engineers the right combination for each grow, sometimes a few technologies, sometimes many, depending on the water and the outcome wanted.
Each feed starts with water, and that water almost always carries other materials with it. Tap water contains chlorine or chloramine and dissolved minerals, often 150 to 300 ppm or more. Chlorine and chloramine can damage root tips and beneficial microbes. Well water varies in minerals and hardness. Rainwater is low in minerals but has little buffering capacity and can carry pathogens and contaminants from the roof and storage. The target pH for cannabis is usually 5.8 to 6.2 in hydroponics and coco, and 6.2 to 6.8 in soil. Warm water holds less dissolved oxygen, and warm, low-oxygen systems increase the risk of root disease.
Cannabis cultivation requires two critical water treatment capabilities: sustained dissolved oxygen delivery to roots for aerobic metabolism, and continuous disinfection of irrigation systems to prevent pathogen colonization and biofilm accumulation. ITS delivers both through a single integrated system. Conventional water treatment achieves dissolved oxygen at about 100% saturation equilibrium, approximately 8 to 9 ppm at room temperature. The ITS nanobubble platform is capable of delivering dissolved oxygen at 500% to 600% supersaturation, forcing gas molecules into solution at concentrations 5 to 6 times beyond equilibrium, and extends the same delivery capability to other oxidizing agents including electrochemically generated chlorine dioxide, ozone, hydrogen peroxide, and custom oxidizers. The platform is capable of up to 600% dissolved oxygen saturation, but systems are not normally run that high.
Conventional aeration creates millimeter-scale bubbles that rise rapidly to the surface, releasing oxygen before reaching deep root zones. Nanobubbles smaller than 200 nanometers have fundamentally different physics. They remain suspended in solution for extended periods, penetrate deep into dense root zones without disturbing root structures, and dissolve gradually where roots need oxygen most. Oxygen is only absorbed by roots when bubble size is smaller than the root's uptake mechanism; nanobubbles meet this requirement, and conventional oxygen systems do not.
Root cells generate all metabolic energy through aerobic respiration, a process that requires oxygen. That energy powers active nutrient uptake via ion pumps in root cell membranes. When dissolved oxygen is insufficient, roots shift to anaerobic metabolism, energy production drops, and nutrient uptake collapses. Cannabis thrives at 15 to 24 ppm dissolved oxygen delivered as nanobubbles at 500%+ supersaturation. While the platform is capable of delivering 40 to 50 ppm and beyond, the 15 to 24 ppm range represents the efficiency sweet spot for cannabis cultivation. At the reservoir, 40+ ppm dissolved oxygen is typical to account for losses in distribution lines, ensuring 20 to 25 ppm reaches the irrigation emitter. High dissolved oxygen enables better nutrient cycling throughout the growth cycle, supporting richer phenotype expression, more complex terpene profiles, and fuller cannabinoid development. It also stabilizes the root environment, so growth patterns are more predictable and repeatable from crop to crop.
Most cannabis operations treat water quality as one-dimensional: they add oxygen. But irrigation systems accumulate biofilm, harbor pathogenic spores such as Pythium and Fusarium, and develop microbial colonies that compete with plant roots for nutrients and oxygen. Standard disinfection methods such as hydrogen peroxide and sodium hypochlorite require chemical storage, carry environmental risks, and can damage beneficial microorganisms. The ITS electrochemical chlorine dioxide generation system produces chlorine dioxide on demand at the point of use, from electricity and sodium chlorite, a single precursor, with no chemical storage and no transportation risk. A precise electrical current applied to a patented cathode-anode cell generates chlorine dioxide directly from the water supply. Chlorine dioxide is generated at controlled concentrations with parts-per-million precision, delivered through the same nanobubble platform as oxygen, and provides precision disinfection of irrigation lines, water tanks, and the root zone. The result is biofilm removal, pathogen suppression, and a clean irrigation system, all without chemical storage or environmental exposure risk.
Through its oxidative action, chlorine dioxide disrupts the cell walls or membranes of microorganisms, neutralizing them and preventing their proliferation. Organisms addressed include bacteria such as E. coli, Salmonella, Listeria monocytogenes, Pseudomonas aeruginosa, Staphylococcus aureus, and Bacillus subtilis; viruses including norovirus, rotavirus, hepatitis A, influenza virus, and tobacco mosaic virus; fungi and molds including yeast, powdery mildew, Botrytis cinerea (grey mold), Aspergillus species, Fusarium, Penicillium, and Alternaria; protozoa including Giardia lamblia and Cryptosporidium; biofilm-forming bacteria and fungi on irrigation systems and water storage tanks; organic contaminants including phenols, hydrogen sulfide, and algae; and cannabis-specific pests including cannabis downy mildew (Peronospora cannabina), Pythium (root rot), and Cladosporium.
Hydrogen peroxide and chlorine require chemical storage, manual dosing that varies, destroy all microbes indiscriminately, remove biofilm only partially, and carry high regulatory complexity around chemical handling, storage, and disposal. Electrochemical chlorine dioxide requires no chemical storage because it is generated on demand, is controlled to parts-per-million precision, is selective in that it kills pathogens while sparing beneficial microbes, removes biofilm comprehensively, and carries low regulatory complexity because there is no stored chemical to handle or dispose of.
RO systems produce clean, high-purity water but strip dissolved oxygen in the process, down to 0 to 2 ppm output. A nanobubble supersaturation system positioned in-line downstream of the RO unit restores dissolved oxygen to 15 to 24 ppm before water enters the reservoir, preserving complete water purity while delivering oxygen at the point of distribution. Optional integration of electrochemical chlorine dioxide disinfection adds pathogen suppression and biofilm removal without chemical storage risk. Together they create a complete water treatment pipeline: purification by RO, then oxygenation, then disinfection, then irrigation.
Cultivation rooms, drying rooms, and processing areas need the highest level of sterilization and cleanliness. ITS combines bipolar ionization, used without creating ozone, with advanced filtration technology for the air, and electrochemical chlorine dioxide, UV, and nano and micro bubble treatment for the water. The combination is engineered for that facility: the grow rooms, the water system, and the sanitation program as one system.
High dissolved oxygen at elevated temperatures reduces or eliminates chiller dependency, since warm water holds less oxygen and accelerates Pythium growth, and most large growers run expensive chiller systems to combat this. Combined dissolved oxygen and electrochemical chlorine dioxide prevents biofilm formation and extends irrigation system lifespan. Beneficial microbes such as Trichoderma, Bacillus, and mycorrhizae only thrive in aerobic, oxygen-rich environments, and indiscriminate disinfection destroys them, while selective chlorine dioxide spares them, so the grower's bio-input investment is protected. Better root respiration means more stable pH, fewer dramatic pH swings, and fewer nutrient lockouts. Early-stage plants are the most oxygen-sensitive, and high dissolved oxygen improves clone rooting success and shortens rooting time. Healthy plants with high dissolved oxygen have superior natural immunity and are less susceptible to powdery mildew and pest pressure. One Pythium outbreak can mean total crop loss, and high dissolved oxygen directly suppresses the anaerobic conditions Pythium requires, while electrochemical chlorine dioxide disinfection attacks the pathogen directly. Consistent dissolved oxygen means fewer manual interventions, and on-demand chlorine dioxide generation eliminates chemical handling, storage, and disposal labor. Dissolved oxygen measurement provides quantifiable, auditable proof of consistent water quality, and on-demand chlorine dioxide generation simplifies regulatory compliance.
A temporary pilot of 4 to 8 weeks includes complete system setup with RO, dissolved oxygen, and optional chlorine dioxide disinfection integration; real-time water quality testing of dissolved oxygen, saturation level, chlorine dioxide concentration, pH, and electrical conductivity; baseline yield, pathogen pressure, and plant health documentation; and the option to purchase the full system at program conclusion. A full system purchase and installation includes custom engineering for the water supply and facility, including RO flow rate and distribution system capacity; professional installation, commissioning, and calibration; operator training and monitoring protocols; and technical support and system optimization through the first 2 to 3 crop cycles.
Supersaturation capability 500% to 600% versus equilibrium of about 100%. Output dissolved oxygen range 15 to 24 ppm (cannabis optimal), scalable to 40+ ppm and beyond. Nanobubble size under 200 nanometers. Stability 24+ hours sustained, with no off-gassing in closed systems. Oxygen transfer efficiency 85%+ gas-to-liquid transfer rate. Flow rate capacity scalable from 5 gallons per minute to 500+ gallons per minute. Electrochemical chlorine dioxide generation with precision control, on demand, and no chemical storage. Platform flexibility across oxygen, chlorine dioxide, ozone, hydrogen peroxide, and custom oxidizers. In-line compatibility with RO systems and existing irrigation infrastructure.
No one size fits all. Each grow is different, and each system is built around that grow's water, crop, and objective. Understand the water. Define the objective. Engineer the process. Measure the result.