Microorganisms in water need to be controlled without adding chemicals that leave residuals or byproducts.
Ultraviolet light damages the DNA of bacteria, viruses, and protozoa so they cannot reproduce. Water passes a UV lamp in a controlled chamber, with dose set by flow and water clarity.
UV disinfection adds nothing to the water. No chemicals, no residuals, no taste or odor change, just controlled light.
Ultraviolet light is electromagnetic radiation with wavelengths from 100 to 400 nanometres, shorter than visible light and longer than X-rays. It disinfects because microbial DNA and RNA absorb UV strongly around 250 to 265 nanometres, forming pyrimidine dimers that prevent the organism from reproducing. UV adds nothing to the water: no chemicals, no residuals, no taste or odor change. It gives no residual protection downstream, so it is normally combined with a residual disinfectant or with filtration where residual control is needed. Dose depends on flow, water clarity (UV transmittance), and the organisms targeted. ITS uses different UV types depending on the water. The right UV is chosen and combined with the other technologies for that application, not one UV for every job.
UVA, 315 to 400 nm, long-wave near UV, has essentially no germicidal value at practical doses and is not a water disinfection band on its own. UVB, 280 to 315 nm, has some germicidal effect but is weak compared with UVC and is not used for water disinfection at practical doses. UVC, 100 to 280 nm, is the germicidal band and the standard for water, air, and surface disinfection. VUV, vacuum UV, roughly 100 to 200 nm, is strongly absorbed by air and only propagates in a vacuum or in water; VUV at 185 nm splits water and oxygen and can generate ozone and hydroxyl radicals, which is why it is used in advanced oxidation and in some TOC destruction applications. Far-UVC, 200 to 230 nm, most commonly 222 nm from a krypton chloride excimer lamp, is an air and surface technology, not a water treatment product, and its use in occupied spaces is governed by exposure guidance. Low-pressure mercury lamps at 253.7 nm UVC are the workhorse of UV disinfection, with high germicidal efficiency, low cost, and long life. Low-pressure high-output and amalgam lamps keep the 253.7 nm emission with several times the output per lamp. Medium-pressure mercury lamps give a broad spectrum, roughly 200 to 400 nm, with lower germicidal efficiency but broad output that breaks down complex organic compounds by photolysis, used where advanced oxidation is needed. UV LED, typically 265, 273, or 280 nm UVC, is a semiconductor diode with instant on and off, no warm-up, no mercury, and long life, used for drinking water, point-of-use disinfection, and small or intermittent systems. Excimer lamps give narrowband output at a chosen wavelength, such as KrCl at 222 nm, ArF at 193 nm, and XeCl at 308 nm, with no mercury. Pulsed xenon lamps give short, intense pulses of broad-spectrum light filtered to emit mainly UVC, used in some hospital settings for environmental surface disinfection.
Industrial water: Low-pressure amalgam lamps (254 nm) are the workhorse for process water, food and beverage, pharma, cooling tower makeup, and RO feed protection. Efficient, long lamp life, good for flows up to moderate size. Medium-pressure lamps: pick these for high flow in a compact reactor, wastewater reuse, and high-dose jobs. They also break down chloramines and quench residual chlorine or ozone. They draw more power and run hotter, so quartz fouling needs attention. 185 nm low-pressure lamps: TOC reduction and polishing in ultrapure water for pharma, semiconductor, and power plants. This is a polishing step, not bulk disinfection. UV advanced oxidation (UV with hydrogen peroxide or chlorine): for trace organics like 1,4-dioxane, taste and odor compounds, and potable reuse. It needs a separate peroxide dosing and quench design. UV-C LEDs: small skids and point-of-use only for now. Output per unit is still too low for most plant-scale flows. Industrial air: In-duct and coil irradiation: low-pressure UV-C in air handlers. This is the most common industrial and healthcare application, and it keeps coils clean and cuts energy loss from biofilm. Upper-room UVGI: high-ceiling spaces like warehouses, cold storage, and production floors with people below the beam. Enclosed recirculation units: air passes the lamp inside a sealed housing, so occupant exposure is not a concern. Pulsed xenon: unoccupied room and surface decontamination between cycles. Far-UV 222 nm: occupied spaces, but the safety data is still developing, so use filtered lamps from vendors with third-party testing. Ozone-free quartz: standard for anything near people or sensitive crops. Lamps with 185 nm output make ozone.
Water: UV transmittance, hardness and fouling, flow range, target organism dose, and sleeve cleaning method (mechanical wipers or chemical). Air: air velocity, residence time, relative humidity, and lamp placement relative to the coil or duct. Validation: third-party bioassay dosing for water, and ASHRAE 185.1 or 185.2 testing for air units. Maintenance: lamp replacement interval, ballast life, and disposal of mercury lamps.