Many operations need reliable disinfection and oxidation, but bulk chemicals bring storage, handling, and dosing problems.
ITS electrochemical chlorine dioxide systems generate chlorine dioxide on demand from sodium chlorite and electricity. No routine acid feed and no routine chlorine feed. The system produces a nearly pure, gas-stripped chlorine dioxide solution at neutral pH, in the range of about 200 to 3,000 mg/L where supported by the generator design, supplier documentation, and operating procedure.
Chlorine dioxide is a selective oxidant. It works across a wide pH range and does not form the same chlorinated byproducts as chlorine. Generated on demand, it is there when needed and not stored as a hazardous stock.
Electrochemical chlorine dioxide dosing system installed in a plant room.
Electrochemical chlorine dioxide is generated on site, on demand, from sodium chlorite and electricity. Inside an electrochemical reactor, the anode supports oxidation and the cathode supports reduction, while electrical current controls the reaction conditions. The system produces chlorine dioxide gas that is introduced into water inside the generator, giving a pH 7 solution delivered by liquid chemical pump or metered suction. A single precursor keeps the process simple: no routine acid feed and no routine chlorine feed, and no need to transport or store large quantities of chemicals. Generation is automated and the design is scalable. Chlorine dioxide works by oxidation rather than chlorination. It disrupts enzyme activity, damages essential proteins, and interrupts cellular processes, acting on several biological systems at once. As a neutral molecule it moves well through water, and nano and micro bubble delivery carries it deeper into water and surfaces.
Food processing facilities use it on surfaces, equipment, and water, including conveyors, produce wash water, and packaging lines. It is the sanitizing step in Clean-in-Place systems for pipes, valves, tanks, and process lines. Breweries use it on tanks, lines, and vessels. Cannabis growers use it for pathogen control in nutrient solutions. Pharmaceutical and nutraceutical operations use it for cleanroom sanitation, equipment and bioreactor decontamination, and seed processing. It also serves wastewater treatment, agriculture and irrigation, aquaculture, municipal drinking water, and hospitals, where it pairs with micro-bubble technology for surface and instrument sanitation.
The generator line starts with compact production around 1 lb. of chlorine dioxide per day, with standard 1, 3, and 6 lb. per day configurations and cell capacity scalable up to 100 lbs. per day for larger applications. A 1 lb. per day unit suits pilot systems, compact treatment points, small facilities, and focused odor or sanitation applications, in a wall-mounted generation and dosing unit with remote electronics enclosure, direct process feed or small solution storage column, local interface, alarm output, permissive interlock, and optional remote alerts. A 3 lb. per day unit suits mid-size process water, storage tank treatment, food and beverage, cooling water, hospitality, and healthcare support, as a wall-mounted or floor-mounted package with expanded dosing and storage, flow pacing, alarm status, cellular alerts, and optional concentration monitoring. A 6 lb. per day unit suits larger industrial, municipal, reuse, cooling, sanitation, agriculture, and multi-point dosing programs, as a floor-mounted, skid-mounted, or engineered package with external tank, high-pressure feed option, and up to two independently controlled distribution pumps, plus remote monitoring, data logging, ORP protection, leak detection, and gas detection options. Systems up to 100 lbs. per day suit high-demand industrial, municipal, centralized treatment, multi-site support, and large process applications, as a custom engineered cell package, skid system, or modular generator platform with engineered storage, pressurized feed, multiple dosing points, and full remote visibility. Utility requirements are 110 to 115 VAC single phase, 20 to 30 amp service depending on options, and 0.9 to 1.2 gallons per minute of supply water at 50 psi minimum on compact systems, with an optional supply-water booster pump and flow package where site pressure or flow is limited. Typical solution production flow is approximately 0.72 to 1.1 gallons per minute on compact systems, and solution feed pressure can be configured up to 105 psi where required.
The platform is designed with safety in mind: a customer-controlled safety permissive interlock can shut down the entire system, automated feed-stop overfeed protection is available, secondary ORP-based overfeed protection is available, an internal leak detection sensor is available, and an optional chlorine dioxide gas detection sensor with emergency shutdown, remote alarm, and exhaust fan output contact can be included. Hydrogen byproduct is safely diluted to less than 0.5% by volume. Byproducts include approximately 2% sodium hydroxide solution, and the anolyte and waste stream may contain sodium chlorite, chlorate, and residual chlorine dioxide depending on configuration and operating conditions. The generation module has a clear removable door for visual inspection, operating verification, and routine maintenance access, and the controls and electronics can be mounted away from the wet generation area in a remote electronics enclosure to protect components and simplify operator access.
Most competing chlorine dioxide technologies can deliver value in the right application, but they often require trade-offs in chemical handling, byproduct profile, residual performance, operator burden, pH sensitivity, capital cost, or biofilm effectiveness. Acid and chlorite systems need acid storage and handling and low-pH chemistry that may require added pH management. Chlorine and chlorite systems need chlorine handling and careful control of excess reactants. Three-chemical systems use more feeds, pumps, and storage and need more operator oversight. The ITS electrochemical platform uses a single precursor, sodium chlorite at 25% or 31% concentration where supported by the current generator design, supplier documentation, materials review, operating procedure, and approvals, and controlled electrical energy converts chlorite ions into chlorine dioxide on demand, with no routine acid or chlorine feed. The output is a neutral-pH, nearly pure, gas-stripped chlorine dioxide solution. The simplified approach supports safer chemical logistics, cleaner equipment rooms, easier operator training, and more predictable on-demand production.
ITS equipment is configured to fit the site: wall-mounted units for compact mechanical rooms and focused treatment points with limited floor space; floor-mounted or freestanding units for permanent equipment rooms needing storage and accessible service layout; skid-mounted packages for multi-cell systems, larger treatment trains, and structured plant integration; modular units for tight niche locations, phased expansion, difficult access paths, and installation around existing equipment; rolling or mobile units for pilots, temporary treatment, emergency response, and seasonal operations; and custom engineered systems for unique footprints, high flows, unusual hydraulics, elevated distribution, multi-building facilities, and containerized systems. Storage and delivery options include direct process feed, storage column, external tank, day-tank supply, high-pressure feed, and multi-point distribution.
Compliance
For U.S. public drinking-water systems, the federal maximum residual disinfectant level for chlorine dioxide is 0.8 mg/L and the maximum contaminant level for chlorite is 1.0 mg/L. The 0.8 mg/L value is a finished-water residual limit, not the concentration of the generated stock solution; ITS systems produce a more concentrated solution and meter or dilute it through an engineered feed system to meet the approved application dose and residual. ITS systems carry ANSI 61 approval and Gold Seal standard seal for specified configurations and water-contact components.